50 kW Diesel Heater
Portable 50 kW diesel heater with digital control and automatic thermostat for temporary industrial heating.
Delivery in the Marmara region within 2-6 hours; across Türkiye within 24 hours.
Technical details
| Heating output | 50 kW |
|---|---|
| Thermal capacity | Approximately 43,000 kcal/h / 170,000 BTU/h |
| Average fuel consumption | 4 L/h; subject to operating conditions |
| Fuel tank | 52 L |
| Auxiliary power supply | 220 V |
| Control | Digital adjustment and automatic thermostat |
| Datasheet material specification | Stainless steel |
| Options | Rental and sale |
Fuel consumption and site performance vary with insulation, air change, outdoor temperature and thermostat setting.
Product and application information
The 50 kW Diesel Heater is specified with 170,000 BTU/h thermal capacity, a 52-litre fuel tank, digital adjustment and an automatic thermostat for temporary industrial heating projects. It supports controlled ambient heating, while the thermostat helps maintain an operating pattern matched to demand. The documented average fuel consumption of 4 L/h may vary with ambient temperature, thermostat setting, insulation and operating time.
This capacity class can be used where a permanent system is not yet operational or heating is only required for the project duration. Planning should consider volume, ceiling height, open doors, air leakage, outdoor temperature and target temperature rather than floor area alone.
Priority applications for the 50 kW class
- Construction and major renovation sitesPlanned temperature support for structural work, fit-out, post-pour activities and temporary production zones.
- Warehouses, logistics centres and loading baysZoned heating for operational areas where door traffic and infiltration make whole-volume heating inefficient.
- Factories, workshops and maintenance shutdownsWarm air for machinery installation, heavy-equipment service, non-production spaces and seasonal work zones.
- Hangars, shipyards and heavy-vehicle workshopsZoned support planned around ceiling height, door openings, combustibles and airflow.
- Concrete, screed, plaster, epoxy and paint processesMeasured temperature support within the material manufacturer's humidity and temperature limits.
- Temporary and emergency heatingSupport for critical operational zones while the permanent system or boiler is unavailable, subject to a suitable ventilation and installation plan.
- Greenhouses, farms and poultry housesUse after reviewing crop- or livestock-level temperature, condensation, air quality, combustion gases and even distribution.
Site conditions and controlled drying
The unit can provide temperature support for concrete, screed and building-drying work, but does not by itself guarantee a drying time or outcome. Relative-humidity measurement, appropriate air movement and dehumidification where required should form part of the project. For concrete, screed, epoxy and other coatings, the material manufacturer's temperature and humidity limits must be maintained, and warm air should not be directed at sensitive surfaces.
The 220 V auxiliary supply for the fan and controls must match the site infrastructure. Fuel safety, combustible clearance, ventilation, combustion-air and exhaust arrangements should be checked before installation. For occupied enclosed spaces such as mosques, wedding venues, sports halls or exhibition tents, only a correctly designed indirect/flued diesel system with exhaust discharged outdoors, or a suitable electric solution, should be considered. Standard heaters must not be used in paint areas with solvent vapour or an explosion classification.
Select the right capacity for your application
Space volume, insulation, operating period and target temperature are evaluated together to determine the suitable model and unit quantity.
Frequently asked questions
Quick answers about selection, application and technical use of 50 kW Diesel Heater.
What is the heating capacity of 50 kW Diesel Heater?
The technical heating capacity of 50 kW Diesel Heater is 50 kW. Final quantity is determined by volume, insulation and target temperature.
What energy or connection infrastructure does 50 kW Diesel Heater require?
The key requirement for 50 kW Diesel Heater is diesel fuel; approx. 4 L/h consumption and a 52 L tank. The circuit and protection devices must be verified by qualified personnel.
Which drying and heating applications use 50 kW Diesel Heater?
50 kW Diesel Heater can be considered for zoned heating in large construction, warehouse, hangar and project areas. Heat distribution and ambient moisture should be monitored by measurement.
What safety check is required when using 50 kW Diesel Heater?
fresh air, exhaust discharge and manufacturer safety instructions must be verified before indoor use Manufacturer instructions and site risks should also be assessed.
How quickly can 50 kW Diesel Heater be delivered?
We deliver within 3 hours in the Marmara Region and across Türkiye within 24 hours at the latest. The exact timing is confirmed based on stock, district and site conditions.